Fire near Heilongjiang (CN)

47.06°N, 130.90°E · first detected on 11 October at 05:49

What the satellites measured

This fire was tracked from 11 October at 05:49 to 17 October at 07:16, that is 6 days, through 561 satellite detections. The detected extent reaches 8,485 ha.

Detected extent
8,485 ha
Cumulative power
2,695 MW
Peak power, one pixel
25 MW
VIIRS and MODIS detections
561
Estimated emissions
235 t of carbon
Carbon burnt in the 0.1 degree cells (about 10 km) around the fire, from 11 October 2026 to 17 October 2026. An order-of-magnitude estimate from GFAS (ECMWF, Copernicus CAMS): it also counts neighbouring fires in the same cell. Contains modified Copernicus Atmosphere Monitoring Service information (2026).

These four figures cover the polar orbits alone, the ones that measure an area. The pass table below also counts geostationary detections, more frequent but too coarse for geometry, and its power column sums a whole pass where the peak above is that of a single pixel.

“Detected extent” is not “burned area”: it is the union of the ground footprints of the satellite pixels, and a pixel counts in full (375 m for VIIRS, 1 km for MODIS) even when only a forest edge is burning. Compared with press figures it is in practice one and a half to three times the area reported. Detections taken at the edge of the scan swath, too coarse to measure anything at all, are excluded. These figures come from thermal detection and are not an official assessment: only the emergency services and the competent authorities are authoritative.

Replay how the fire spread

The map is framed on this fire's footprint and loads only its detections. The timeline below covers the period in which satellites saw it, from the first to the last detection, with twelve hours before and twenty-four after; the ticks on the bar mark the emergency services' announcements that fall within it. The cursor opens on the most powerful pass, and playback replays the whole fire in about thirty seconds. “1 h” shows what is burning within an hour of the chosen moment : the map then follows the power curve below and empties when it falls. “24 h” stacks twenty-four hours : a fire stays visible between two satellite passes, which come two to four times a day. Both are true, but they say different things.

How the radiative power evolved

One point per satellite pass: the sum of the fire radiative power measured over the fire. This is the curve that says whether the fire eased off or picked up again, which no cumulative figure shows. The window covers 9 days; beyond that, clustering would merge two successive fires in the same place.

Fire dynamics

Loading history…

Satellite passes in detail

PassPower summed over the passDetectionsSensor
17 October at 07:1631 MW9N
17 October at 06:38483 MW82N21
17 October at 05:53435 MW106N20
17 October at 05:34245 MW53N
17 October at 04:58108 MW19N21
16 October at 07:5027 MW2Aqua
16 October at 06:57163 MW35N21
16 October at 06:14243 MW64N20
16 October at 05:15139 MW23N21
15 October at 06:32154 MW31N20
15 October at 06:12223 MW49N
15 October at 05:36170 MW28N21
15 October at 04:5155 MW9N20
14 October at 08:148 MW1Aqua
14 October at 06:3251 MW14N
14 October at 05:5371 MW16N21
14 October at 05:1039 MW11N20
14 October at 04:5113 MW2N
11 October at 06:063 MW1N20
11 October at 05:493 MW1N

8 other fires near Heilongjiang (CN)

Separate fires, apart in time or in space, not pieces of this one. A single municipality can have several over one summer, and a forest massif often covers more than a hundred square kilometres.

Follow live

The map shows active fires in 3D, with smoke plumes, forecast wind, drop zones and the live position of water bombers tracked by ADS-B, anywhere in the world.

Open the fire map

Take the data of this fire with you

A ready-to-use archive, paid once, no subscription. It contains:

From €20.00 excl. VAT, six formats to choose from, link valid for 30 days.

Download the data

Pro subscribers: included. €49 excl. VAT a month, no commitment. The public map stays free. Discover GISFire Pro

© 2026 SARO · Gistin. All rights reserved. The interface, its presentation and the contents of GISFire are protected; reproducing or imitating them requires written permission. The source data remain the property of their respective producers, see the credits.

Legal notice · Privacy policy ·  · GISFire v2.4.2